Specifications:
1.Capacity:50kg to 635kg .
2.High accuracy, C3.
3.Alumium construction
4.With OIML approval.
Related Product Searches:Load cell L6F,High Quality,Load cell L6F, Sensor,L6F
L6F load cells are available in the capacities 50kg to 2000kg. Alumium construction, silicone adhesive sealed,surface anodized and anti-corrosion.Intergral structure and easy installation.They are suitable for pricing scale, platform scale and other electronic weighing devices. | Important FeaturesCapacities:50kg to 2000kg .High accuracy.Alumium parallel beam construction. Max. platform size:50-200kg 600x600mm.250-500kg 600x800mm.750-2000kg 1200x1200mmIntergral installation.With OIML approval. |
Specifications
Capacity | (kg) | 50/100/150/200/250/500/750/1000/2000 | |||
Input sensitivity | (mv/v) | 2.0±0.2 | |||
Accuracy class | C3D | C3 | C3G | ||
Maximum number of verification intervals |
| 2500 | 3000 | 4000 | |
Minimum load cell verification interval | (g) | Emax/5000 | Emax/7000 | Emax/11000 | |
Temperature effect on zero | (%FS/10) | 0.0280 | 0.0200 | 0.0127 | |
Temperature effect on sensitivity | +20--+40 | (%FS/10) | 0.0210 | 0.0175 | 0.0131 |
-10--+20 | 0.0140 | 0.0117 | 0.0088 | ||
Combined error | (%FS) | 0.0300 | 0.0200 | 0.0150 | |
Creep | (%FS) | 0.0200 | 0.0167 | 0.0125 | |
Input resistance | (Ω) | 406±6 | |||
Output resistance | (Ω) | 350±3 | |||
Insulation resistance | (MΩ) | ≥5000 | |||
Zero balance | (%FS) | 2 | |||
Temperature,compensated | () | -10--+40 | |||
Temperature,operating | () | -20--+50 | |||
Excitation, Recommended | (V) | 5--15 | |||
Safe overload | (%FS) | 150 | |||
Ultimate overload | (%FS) | 300 |